Description
Distinctive features:
Functions:
- soft acceleration and deceleration
- potential-free control input for soft acceleration and deceleration
- separately adjustable parameters accel. time, start voltage, decel. time, current limiting, rated device current and tripping class
- boost-start selectable
- potential-free relay output for operating state
- transistor output — unit bypassed
Distinctive features:
- three-phase controlled soft starter
- controlled by microcontroller
- optimized soft start and current control
- connection in the motor delta winding (cost saving via smaller rating)
- current and torque reduction during acceleration
- easy mounting, for snap-mounting on 35 mm standard rail
- integrated bypass relay
- parameterization by means of potentiometers
- no mains neutral conductor (N) required
- economically priced substitute for star-delta starters
- spring-loaded terminals
- heat sink temperature monitoring
- compact design, 45mm up to 25A and 52,5mm at 45A
- degree of protection IP20
- motor protection
- thermal device protection
Manufacturer: | Peter Electronic |
Series: | VersiStart III (9А - 45А) |
Model: | VS III 400-9 |
Application: | pumps / fans / general purpose |
Capacity, kW: | 4 |
Current, А: | 9 |
Main power supply, V: | 400 |
Phase: | 3 |
Output frequency, Hz: | 50/60 |
Enclosure: | IP 20 |
Acceleration time, sec: | 0,5-10 |
Deceleration time, sec: | 0,25-10 |
Operation temperature, °С: | 0.....+45 |
Max. switching cycle per hour: | 50 |
Starting current, % of rated current: | 200-500 |
Integrated bypass relay: | + |
Control type: | analog |
Microprocessor supply voltage: | 24 V DC, 230 V АC |
Motor protection (thermal model): | + |
Motor protection (input for thermistor/thermal relay): | - |
Motor protection (low current) : | - |
Motor protection (momentary motor overload): | - |
Motor protection (Others): | + |
JOG mode: | - |
DC braking: | - |
Inputs/Outputs: | control input, 2 relay outputs, transistor output |
Separately adjustable parameters: | 6 |
Mounting: | 35 mm rail |
Options: | Special voltages of 230 V and 480 V, wide voltage range 200-480 V with external control voltage AC 230B (option V), signaling contact (start of acceleration to braking complete) (M option) |