Product Attribute | Attribute Value | Search |
---|---|---|
Input Type | Voltage | |
Input, Range | 50 to 270 V ac⁄dc | |
Maximum Operating Temperature | 50 °C | |
Minimum Operating Temperature | 0 °C | |
Module Type | Voltage Converter | |
Mounting Type | Self-Stick Pad | |
Number of Channels | 2 | |
Output Type | Voltage | |
Series | VCM Series | |
Special Features | Converts AC/DC Voltages to an Acceptable Signal Input for Many RLC Counters and Accessories and Provides I/O Voltage Isolation | |
Supply Voltage | 50 to 270 V ac⁄dc | |
Temperature Operating Range | 0 to +50 °C | |
Termination | 6 in. Leads | |
Type | Signal Converter |
\n\n
Overview
These modules provide a convenient way to adapt RLC Counters to most any machine control voltage signal. They also make it easy to upgrade electromechanical counter installations with RLC Counters. VCM's are available in two input voltage ranges that cover the spectrum from 4-270 V. The non-polarized input of these modules will accept A.C. (50/60 Hz) or D.C. voltages at input cycles up to 30 Hz. The output uses MOSFET technology that is compatible with either the L.S. Count or Remote Reset inputs of RLC Counters. Electrical isolation between input and output is achieved by means of an internal opto-isolator rated at 2300 VRMS