Description
Mass flow accuracy (Liquid): ±0.15% of rate Mass flow repeatability (Liquid): ±0.05% of rate Volume flow accuracy (Liquid): ±0.25% of rate Volume flow repeatability (Liquid): ±0.05% of rate Mass flow accuracy (Gas): ±0.50% of rate Mass flow repeatability (Gas): ±0.05% of rate Density accuracy (Liquid): ±0.002 g/cm3 (±2.0 kg/m3) Density repeatability (Liquid): ±0.0005 g/cm3 (±0.5 kg/m3) Temperature accuracy: ±1 °C ±0.5% of reading Sensor maximum working pressure: 1,450 psig (100 barg) Meter approvals, calibrations, and certifications: •UL•CSA•ATEX•ASME•3-A•USDA•EHEDG Output variables: •Mass & volume flow •Net product content / flow •Temperature •Density •Concentration Local display: None Power: •Minimum 19.2 to 28.8 VDC •6.3 watts •Meets Installation (Overvoltage) Category II, Pollution Degree 2 requirements Input/output signals: •One active 4–20 mA output •One active frequencty output HART: Bell 202 signal is superimposed on the primary milliamp output Mounting options: •Mounted on 35 mm rail •Rail must be grounded Application types: •Continuous process control •Two-phase flow/entrained gas •Meter verification Hazardous approvals: Suitable for non-hazardous environments only