Description
FC-102P55KT4E55H2XGXXXXSXXXXA0BXCXXXXDX
Product details
Gross weight | 42.6 kg | ||
Net weight | 41.2 kg | ||
Volume | 228.095 l | ||
EAN | 5702427509771 |
Sales restriction control
Matr grp for sales restriction | 0001 |
VLT® HVAC DRIVE FC 100 SERIES
Product Group | (FC-) VLT® HVAC Drive FC- | ||
Series | 102 | ||
Power Rating | (P55K) 55 KW / 75 HP | ||
Phase | (T) Three phase | ||
Mains Voltage | (4) 380 - 480 VAC | ||
Enclosure | (E55) IP55 / Type 12 | ||
RFI Filter | (H2) RFI Class A2 (C3) | ||
Brake - Safe Stop | (X) No brake chopper | ||
LCP | (G) Graphical Loc. Cont. Panel | ||
Coating PCB | (X) Not coated PCB | ||
Mains Option | (X) No Mains Option | ||
Adaptation A | (X) Standard Cable Entries | ||
Adaptation B | (X) No adaptation | ||
A Option | (A0) PROFIBUS DP MCA 101 | ||
Software Release | (SXXX) Latest release std. SW. | ||
B Option | (BX) No B Option | ||
Software Language Pack | (X) Standard Language Pack | ||
C0 Option MCO | (CX) No C0 option | ||
C1 Option | (X) No C1 option | ||
C Option Software | (XX) No software option | ||
D Option | (DX) No D option | ||
Frame Size | C1 | ||
Typecode Part 1 | FC-102P55KT4E55H2XGX | ||
Typecode Part 2 | XXXSXXXXA0BXCXXXXDX | ||
Calculated Gross Weight | 45.3 | ||
Calculated Net Weight [kg] | 45 | ||
Cross-Plant Configurable Mater | 100_SER | ||
Division | 09 | ||
Material Gross Weight | 42.6 | ||
Material Net Weight | 41.2 | ||
Modelcode01 | FC-102P55KT4E55H2XGX | ||
Modelcode02 | XXXSXXXXA0BXCXXXXDX | ||
Product Catalog | Global (Standard) | ||
Product Group | A97 | ||
Product Hierarchy | 09A9760260376 | ||
Product View (Switch) | Global (Standard) | ||
Recommended Factory | Cannot Determine Vendor | ||
Vendor | Cannot Determine Vendor |
Product details
Gross weight | 42.6 kg | ||
Net weight | 41.2 kg | ||
Volume | 228.095 l | ||
EAN | 5702427509771 |
Sales restriction control
Matr grp for sales restriction | 0001 |
VLT® HVAC DRIVE FC 100 SERIES
Product Group | (FC-) VLT® HVAC Drive FC- | ||
Series | 102 | ||
Power Rating | (P55K) 55 KW / 75 HP | ||
Phase | (T) Three phase | ||
Mains Voltage | (4) 380 - 480 VAC | ||
Enclosure | (E55) IP55 / Type 12 | ||
RFI Filter | (H2) RFI Class A2 (C3) | ||
Brake - Safe Stop | (X) No brake chopper | ||
LCP | (G) Graphical Loc. Cont. Panel | ||
Coating PCB | (X) Not coated PCB | ||
Mains Option | (X) No Mains Option | ||
Adaptation A | (X) Standard Cable Entries | ||
Adaptation B | (X) No adaptation | ||
A Option | (A0) PROFIBUS DP MCA 101 | ||
Software Release | (SXXX) Latest release std. SW. | ||
B Option | (BX) No B Option | ||
Software Language Pack | (X) Standard Language Pack | ||
C0 Option MCO | (CX) No C0 option | ||
C1 Option | (X) No C1 option | ||
C Option Software | (XX) No software option | ||
D Option | (DX) No D option | ||
Frame Size | C1 | ||
Typecode Part 1 | FC-102P55KT4E55H2XGX | ||
Typecode Part 2 | XXXSXXXXA0BXCXXXXDX | ||
Calculated Gross Weight | 45.3 | ||
Calculated Net Weight [kg] | 45 | ||
Cross-Plant Configurable Mater | 100_SER | ||
Division | 09 | ||
Material Gross Weight | 42.6 | ||
Material Net Weight | 41.2 | ||
Modelcode01 | FC-102P55KT4E55H2XGX | ||
Modelcode02 | XXXSXXXXA0BXCXXXXDX | ||
Product Catalog | Global (Standard) | ||
Product Group | A97 | ||
Product Hierarchy | 09A9760260376 | ||
Product View (Switch) | Global (Standard) | ||
Recommended Factory | Cannot Determine Vendor | ||
Vendor | Cannot Determine Vendor |